Department of Electronics and Electrical Engineering
Indian Institute of Technology Guwahati
Guwahati-781039, India

EEE Department, IIT Guwahati

Dr. Sisir Kumar Nayak

pkb
Ph.D. Indian Institute of Science, Bangalore
Designation: Associate Professor

Dr. Sisir Kumar Nayak joined the institute in 2011.

Contact Details
Office Address: Room No. 006, EEE Department, IIT Guwahati, Guwahati-781039, INDIA.
Phone: +91-361-2582530 (O)
Fax: +91-361-2582542
Email: sknayak[AT*]iitg.ernet.in

Research Areas
  • Power flow analysis in AC and DC traction power system
  • Electromagnetics
  • Lightning interaction with an electrical and mechanical system
  • High Voltage Engineering
Courses
Current Courses
  1. EE101- Electrical Sciences (Tutorials)
Selected Publications

Journals
  • S. K. Nayak, M. Joy Thomas, “Lightning induced current and voltage on the rocket in the presence of its trailing exhaust plume”, IEEE Transactions on Electromagnetic Compatibility. Vol 52, No. 1, Feb 2010, pp 117-127.
  • S. K. Nayak, M. Joy Thomas, “Electrical characterization of airborne vehicle exhaust plume”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol 16, No-2, April 2009, pp 325-334.
  • S. K. Nayak, M. Joy Thomas, “An integro-differential equation technique for the computation of radiated EMI due to corona on HV power transmission lines”, IEEE Transactions on Power Delivery, Vol 20, No-1, Jan 2005, pp 488-493.

Conference Publications
  • S. K. Nayak, M. Joy Thomas, “Influence of the exhaust plume on the lightning induced voltage and current on an airborne vehicle”, European Electromagnetics (EUROEM 2008), 21st-25th July 2008, Swiss Federal Institute of Technology (EPFL), Lausanne, Switzerland, pp 25.
  • S. K. Nayak, M. Joy Thomas, “Influence of soil impulse resistance on the lightning induced voltage and current on a launch vehicle at lift off”, 29th International conference on lightning protection (ICLP), 23rd-26th June 2008, Uppsala, Sweden, vol-5b-3, pp 1-12.
  • S. K. Nayak, M. Joy Thomas, “Radiated lightning electromagnetic fields at different heights above ground”, 28th International conference on lightning protection (ICLP), Vol 1, 18-22 Sep 2006, Kanazawa-Japan, pp 357-362.
  • S. K. Nayak, M. Joy Thomas, “Lightning induced voltage on rocket and its exhaust plume”, Proceedings of the International Conference on Electromagnetic Interference and Compatibility, 21-23 Feb 2006, pp 402-409, Bangalore.
  • S. K. Nayak, M. Joy Thomas, “A novel technique for the computation of radiated EMI due to corona on HV transmission lines”, IEEE International Symposium on Electromagnetic Compatibility, Boston, USA, Vol 2, 18-22 Aug 2003, pp 738-742.
  • S. K. Nayak, M. Joy Thomas, “Effect of line length on the radiated electromagnetic interference due to corona on HV transmission line”, 6th International Power Engineering Conference (IPEC03), Vol-1, 27-29 Nov. 2003, Singapore, pp 264-269.
  • S. K. Nayak, M. Joy Thomas, “Computation of EMI fields generated due to corona on high voltage over head power transmission lines”, Proceedings of the International Conference on Electromagnetic Interference and Compatibility, 21-23 Feb 2002, pp 15-19, Bangalore.